Skip to content
Security Briefings

CISA adds 10 exploited flaws to KEV—five in Mitel MiCollab, a root command injection in HPE Juniper Session Smart, a Xen Orchestra auth bypass and three in Danfoss AK-SM 800A—most due Nov 28

On Nov 25, CISA added 10 vulnerabilities to its Known Exploited Vulnerabilities catalog based on evidence of active exploitation: five in the Audio, Web and Video Conferencing (AWV) component of Mitel MiCollab; a root-level command injection via a crafted salt minion ID in HPE Juniper Session Smart Conductor and Router (CVE-2026-103406); an authentication bypass to admin in Vates Xen Orchestra using a token containing an empty JSON object (CVE-2026-133469); and three in Danfoss AK-SM 800A system managers. Eight carry a Nov 28 federal due date and two Dec 9; ransomware use is listed as unknown for all.

Incident Snapshot

Affected products
Mitel MiCollab AWV (CVE-2026-133275, -133303, -133311, -133323, -133324); HPE Juniper Session Smart Conductor/Router (CVE-2026-103406); Vates Xen Orchestra (CVE-2026-133469); Danfoss AK-SM 800A (CVE-2023-25914, CVE-2023-25915, CVE-2025-41450)
Incident type
KEV additions based on evidence of in-the-wild exploitation, with remediation required of U.S. civilian federal agencies under BOD 26-04
Entry point and deadlines
MiCollab: unauthenticated arbitrary file upload, XML injection leading to command execution, OS command injection and authentication bypass; Juniper: root command execution via a crafted salt minion ID; Xen Orchestra: admin access with a token containing an empty JSON object; Danfoss: path traversal via the XML interface and remote command execution. Eight are due Nov 28, 2026; CVE-2026-133311 and CVE-2025-41450 are due Dec 9
Attribution boundary
Exploitation established by CISA; ransomware-campaign use is unknown for all ten and no actor is named
Data impact
CISA does not disclose how many organizations were affected or whether data was stolen
Official response
Apply vendor fixes or mitigations; several entries (e.g., the MiCollab command and XML injections and the Juniper command injection) require forensic triage under BOD 26-04; discontinue use if no mitigation exists

Incident Details & Technical Context

CISA’s Nov 25, 2026 alert added ten KEV entries at once. The five Mitel MiCollab AWV flaws cover file upload, XML injection, command injection, weak authentication and a “not failing securely” bypass that unauthenticated attackers could chain; the HPE Juniper Session Smart flaw yields root command execution; the Xen Orchestra flaw grants admin directly; the three Danfoss AK-SM 800A flaws are older (including 2023 CVEs) and were added now that in-the-wild exploitation has been observed.

The KEV catalog lists a Nov 28 federal due date for eight entries and Dec 9 for CVE-2026-133311 (MiCollab weak authentication) and CVE-2025-41450 (Danfoss information exposure). Entries such as the MiCollab command and XML injections require forensic triage under BOD 26-04, i.e., checking whether systems were compromised before patching. Mitel’s advisory is MISA-2026-0012 (per the KEV notes). The alert does not name victims, actors or the scale of exploitation.

Takeaway: unified-communications gateways such as MiCollab, SD-WAN conductors, virtualization management consoles and building or refrigeration controllers are often internet-exposed and missing from asset inventories. Beyond patching, include them in pre-patch compromise checks. Still undisclosed: exact affected version ranges, how widely each flaw is being exploited, and whether any ransomware group is involved.

Verification & Actions

  • Inventory internet-facing Mitel MiCollab servers (especially the AWV conferencing portal), upgrade per MISA-2026-0012, and look for recently added executable or script files in web directories and unusual XML requests.
  • Confirm that the management plane and salt ports of HPE Juniper Session Smart Conductors/Routers are reachable only internally; after upgrading, audit root-level command execution and newly registered minions.
  • Check whether Xen Orchestra is internet-exposed; after upgrading, review admin sessions and recent VM creation, snapshot export and deletion logs.
  • Find Danfoss AK-SM 800A and similar refrigeration or building controllers reachable from the internet, move them behind a VPN and replace default or shared passwords.
Primary advisory · cisa.govVA - Vulnerability Assessment