CISA adds 10 exploited flaws to KEV—five in Mitel MiCollab, a root command injection in HPE Juniper Session Smart, a Xen Orchestra auth bypass and three in Danfoss AK-SM 800A—most due Nov 28
On Nov 25, CISA added 10 vulnerabilities to its Known Exploited Vulnerabilities catalog based on evidence of active exploitation: five in the Audio, Web and Video Conferencing (AWV) component of Mitel MiCollab; a root-level command injection via a crafted salt minion ID in HPE Juniper Session Smart Conductor and Router (CVE-2026-103406); an authentication bypass to admin in Vates Xen Orchestra using a token containing an empty JSON object (CVE-2026-133469); and three in Danfoss AK-SM 800A system managers. Eight carry a Nov 28 federal due date and two Dec 9; ransomware use is listed as unknown for all.
Incident Snapshot
- Affected products
- Mitel MiCollab AWV (CVE-2026-133275, -133303, -133311, -133323, -133324); HPE Juniper Session Smart Conductor/Router (CVE-2026-103406); Vates Xen Orchestra (CVE-2026-133469); Danfoss AK-SM 800A (CVE-2023-25914, CVE-2023-25915, CVE-2025-41450)
- Incident type
- KEV additions based on evidence of in-the-wild exploitation, with remediation required of U.S. civilian federal agencies under BOD 26-04
- Entry point and deadlines
- MiCollab: unauthenticated arbitrary file upload, XML injection leading to command execution, OS command injection and authentication bypass; Juniper: root command execution via a crafted salt minion ID; Xen Orchestra: admin access with a token containing an empty JSON object; Danfoss: path traversal via the XML interface and remote command execution. Eight are due Nov 28, 2026; CVE-2026-133311 and CVE-2025-41450 are due Dec 9
- Attribution boundary
- Exploitation established by CISA; ransomware-campaign use is unknown for all ten and no actor is named
- Data impact
- CISA does not disclose how many organizations were affected or whether data was stolen
- Official response
- Apply vendor fixes or mitigations; several entries (e.g., the MiCollab command and XML injections and the Juniper command injection) require forensic triage under BOD 26-04; discontinue use if no mitigation exists
Incident Details & Technical Context
CISA’s Nov 25, 2026 alert added ten KEV entries at once. The five Mitel MiCollab AWV flaws cover file upload, XML injection, command injection, weak authentication and a “not failing securely” bypass that unauthenticated attackers could chain; the HPE Juniper Session Smart flaw yields root command execution; the Xen Orchestra flaw grants admin directly; the three Danfoss AK-SM 800A flaws are older (including 2023 CVEs) and were added now that in-the-wild exploitation has been observed.
The KEV catalog lists a Nov 28 federal due date for eight entries and Dec 9 for CVE-2026-133311 (MiCollab weak authentication) and CVE-2025-41450 (Danfoss information exposure). Entries such as the MiCollab command and XML injections require forensic triage under BOD 26-04, i.e., checking whether systems were compromised before patching. Mitel’s advisory is MISA-2026-0012 (per the KEV notes). The alert does not name victims, actors or the scale of exploitation.
Takeaway: unified-communications gateways such as MiCollab, SD-WAN conductors, virtualization management consoles and building or refrigeration controllers are often internet-exposed and missing from asset inventories. Beyond patching, include them in pre-patch compromise checks. Still undisclosed: exact affected version ranges, how widely each flaw is being exploited, and whether any ransomware group is involved.
Verification & Actions
- Inventory internet-facing Mitel MiCollab servers (especially the AWV conferencing portal), upgrade per MISA-2026-0012, and look for recently added executable or script files in web directories and unusual XML requests.
- Confirm that the management plane and salt ports of HPE Juniper Session Smart Conductors/Routers are reachable only internally; after upgrading, audit root-level command execution and newly registered minions.
- Check whether Xen Orchestra is internet-exposed; after upgrading, review admin sessions and recent VM creation, snapshot export and deletion logs.
- Find Danfoss AK-SM 800A and similar refrigeration or building controllers reachable from the internet, move them behind a VPN and replace default or shared passwords.